.. _administration-faq:
Administration FAQ
==================
.. topic:: Duplicate log entries when using :func:`log()` function
Because GenieACS uses a full fledged scripting language for device
configuration, the only way to guarantee that it has satisfied the 'desired
state' is by repeatedly executing the script until there's no more
discrepancies with the current device state. Though it may seem like this
will cause duplicate requests going to the device, this isn't actually the
case because device configuration are stated declaratively and that the
scripts themselves are pure functions in the context of a session (e.g.
Date.now() always returns the same value within the session).
To illustrate with an example, consider the following script:
.. code:: javascript
declare("Device.param", null, {value: 1});
commit();
declare("Device.param", null, {value: 2});
This will set the value of the 'Device.param' to 1, then to 2. Then as the
script is run again the value is set back to 1 and so on. A stable state will
never be reached so GenieACS will execute the script a few times until it
gives up and throws a fault. This is an edge case that should be avoided. A
more typical case is where the script is run once or twice. Essentially if an
execution doesn't result in any request to the CPE or a change in the data
model then a stable state is deemed to have been reached.