@@ -0,0 +1,28 @@
|
||||
.. _administration-faq:
|
||||
|
||||
Administration FAQ
|
||||
==================
|
||||
|
||||
.. topic:: Duplicate log entries when using log() function
|
||||
|
||||
Because GenieACS uses a full fledged scripting language for device
|
||||
configuration, the only way to guarantee that it has satisfied the 'desired
|
||||
state' is by repeatedly executing the script until there's no more
|
||||
discrepancies with the current device state. Though it may seem like this
|
||||
will cause duplicate requests going to the device, this isn't actually the
|
||||
case because device configuration are stated declaratively and that the
|
||||
scripts themselves are pure functions in the context of a session (e.g.
|
||||
Date.now() always returns the same value within the session).
|
||||
|
||||
To illustrate further, consider following script:
|
||||
|
||||
.. code:: javascript
|
||||
|
||||
declare("Device.param", null, {value: 1});
|
||||
commit();
|
||||
declare("Device.param", null, {value: 2});
|
||||
|
||||
This will set the value of the 'Device.param' to 1, then to 2. Then as the
|
||||
script is run again the value is set back to 1 and so on. A stable state will
|
||||
never be reached so GenieACS will execute the script a few times until it
|
||||
gives up and throws a fault.
|
||||